Showing results: 976 - 990 of 1489 items found.
-
SMX-4XXX (Matrix Switches) -
AMETEK VTI Instruments
The VTI SMX-4xxx Series of matrix cards deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Available models with software configurable switch subsystems increase flexibility and help control costs by allowing a single module to be used for different testing requirements. Embedded virtual schematic control further simplifies setup and debugging, allowing all relays to be engaged independent of application software.
-
40-750-521 -
Pickering Interfaces Ltd.
The 40-750-521 is an 8x2 RF Matrix Module suitable for switching frequencies up to 1000MHz. It has a 50Ω characteristic impedance with front panel mounted SMA coaxial connectors. The matrix intended for the easy construction of high performance bidirectional switching systems.
-
42-728A-002 -
Pickering Interfaces Ltd.
The 40-728A-001 (PXI) and 42-728A-001 (PXIe) are 16x2 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
40-728A-002 -
Pickering Interfaces Ltd.
The 40-728A-001 (PXI) and 42-728A-001 (PXIe) are 16x2 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
42-729A-002 -
Pickering Interfaces Ltd.
The 40-729A-001 (PXI) and 42-729A-001 (PXIe) are 8x4 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
40-729A-002 -
Pickering Interfaces Ltd.
The 40-729A-001 (PXI) and 42-729A-001 (PXIe) are 8x4 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
42-728A-002-L -
Pickering Interfaces Ltd.
The 40-728A-002-L (PXI) and 42-728A-002-L (PXIe) are 16x2 50 Ω RF matrices with MS-M Multiway connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
40-728A-002-L -
Pickering Interfaces Ltd.
The 40-728A-002-L (PXI) and 42-728A-002-L (PXIe) are 16x2 50 Ω RF matrices with MS-M Multiway connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
40-725-751 -
Pickering Interfaces Ltd.
The 40-725 is an 8x9 RF Matrix Module suitable for switching frequencies up to 500MHz (50Ω version). The 40-725 is available in either 50Ω or 75Ω versions with SMB coaxial connectors. It is intended for the easy construction of high performance bidirectional matrix switching systems. Automatic Isolation Switches are located on all coaxial connections, these disconnect the matrix from the external test fixture maximizing isolation and RF performance.
-
40-877A-102 -
Pickering Interfaces Ltd.
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-101 -
Pickering Interfaces Ltd.
The 40-837A-101 (PXI) and 42-837A-101 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-877A-002 -
Pickering Interfaces Ltd.
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-837A-101 -
Pickering Interfaces Ltd.
The 40-837A-101 (PXI) and 42-837A-101 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-001 -
Pickering Interfaces Ltd.
The 40-837A-001 (PXI) and 42-837A-001 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.